AFE General Purpose 28-Pin TSSOP T/R
The TDC1011-Q1 is a fully integrated analog front-end (AFE) for ultrasonic sensing measurements of liquid level, fluid identification/concentration, and proximity/ distance applications common in automotive, industrial, medical, and consumer markets. When paired with an MSP430/C2000 MCU, power, wireless, and source code,Ultrasonic AFE offers programmability and flexibility to accommodate a wide-range of applications and end equipment. The TDC1011-Q1 can be configured for multiple transmit pulses and frequencies, gain, and signal thresholds for use with a wide-range of transducer frequencies (31.25kHz to 4MHz) and Q-factors. Similarly, the programmability of the receive path allows ultrasonic waves to be detected over a wider range of distances/tank sizes and through various mediums.Selecting different modes of operation, the TDC1011-Q1 can be optimized for low power consumption, making it ideal for battery powered applications. The low noise amplifiers and comparators provide extremely low jitter, enabling picosecond resolution and accuracy.
- Automotive AEC-Q100 (TDC1011-Q1)
- Measurement Range: up to 8 ms
- Operating Current: 1.8 µA (2 SPS)
- Transmitter Channel TX
- Supports Single Transducer Applications
- Programmable Excitation: 31.25 kHz to 4 MHz, up to 31 Pulses
- Receiver Channel RXoSTOP Cycle-to-Cycle Jitter: 50 psRMS
- Low-Noise and Programmable Gain Amplifiers
- Access toSignal Chain for External Filter Design
- Programmable Threshold Comparator for EchoQualification
- Programmable Low Power Mode for Long TOF Measurements
- Temperature MeasurementoInterface to Two PT1000/500 RTDs
- RTD-to-RTD Matching Accuracy 0.02°CRMS
- Operating Temperature Range: -40°C to 125°C
Especificaciones
| Brand | Texas Instruments |
|---|---|
| Operating | 6.2 mA |
| Product description | 9.7 x 4.4 x 1.05(Max) |
| Schedule B | 8542390000 |
| HTSN | 8542390001 |
| Country of origin | United States |
| Lead Finish | Tin |
SKU: TDC1011QPWRQ1